Product

Home / Product

WIKA

PASCAL 100 -- Hand-Held Multifunction Calibrator

Category: PRESSURE, CALIBRATORS, ELECTRICAL

Model: Portable Calibrators, Portable Calibrator, ELECTRICAL

Avaibility: AVAILABLE

Call For Price

General

Due to its versatility the hand-held multifunction calibrator Pascal series is ideally suited for on-field testing and calibration of industrial measuring instruments. The typical application is the calibration of pressure transmitters, temperature transmitters, pressure gauges, temperature probes and other measuring instruments. The calibration data are stored in the instrument’s memory. The communication with a PC is used to remotely control the unit and to download the calibration reports.

The Pascal 100 is the most advanced portable multifunction calibrator for the measurement and simulation of the following parameters: relative and absolute pressure, electrical signals (mA, mV, V, ?), temperature (TC, RTD), frequency and pulse. In addition, there is the possibility to include an optional HART® module which allows communication with HART® instruments.

Features

The calibrator Pascal 100 has a new large touchscreen display with a new intuitive user-friendly interface, that allows an easy and fast configuration of the calibrator. The availability of ATEX approval II 2G Ex ib IIC T4 Gb - Tamb: -10 ... +50 °C expands the possible applications of this calibrator into hazardous areas (only for Pascal 100/IS). Even in the ATEX version the DC 24 V voltage supply for external transmitters is available. The calibrator has four measurement channels and is thus capable to carry out up to four simultaneous measures. For more flexibility on on-field calibrations, the Pascal 100 has an on-board memory for data storage that allows the evaluation of logged measuring values and calibration reports. In laboratory applications the real-time communication allows the remote control of the Pascal 100 from a PC.

The Pascal 100 can be modularly configured with up to two input and two output modules as well as one HART® module and one output module, which are galvanically isolated from each other. The measurement/simulation of the electrical signals or temperature as well as up to six pressure sensors (four internal and two external sensors) enables the operator to configure the calibrator according to his specific requirements. The environmental parameters module (option) is another plus of Pascal 100, it allows the monitoring of the barometric pressure, the ambient temperature and the relative humidity. The values will be stored in the calibration report.

Pressure

The Pascal 100 has an integrated pressure/vacuum generation by means of a built in hand pump from -0.9 ... +21 bar (-13 ... +300 psi). The presence of a fine precision regulator allows the operator to adjust small pressure increments. Many different pressure configurations are available, e.g.: ? in combination with internal pressure sensors that can be connected to the internal pump (up to 21 bar / 300 psi) ? in combination with external pressure sensors that can be connected directly to the external plugs. Low pressure internal sensors are protected against overpressure by means of protection valves. High flexibility in measurement is given by the availability of multiple pressure engineering units.

Applications

  • Calibration service companies and service industry
  • Measurement and control laboratories
  • Quality assurance

Special features

  • Measurement and simulation of the following parameters: pressure, electrical signals (mA, mV, V, ?), temperature (TC, RTD), frequency and pulse
  • Large colour display with touchscreen with new intuitive and user-friendly interface
  • Internal pressure/vacuum generation
  • Option: intrinsically safe version II 2G Ex ib IIC T4 Gb - Tamb: -10 ... +50 °C
  • Option: integrated HART® module for communication with HART® instruments

Base instrument

Indication

Display

Touchscreen + 5 keys

Dimension

640 x 480 Dots
Dot size: 0.06 x 0.06 mm (0.002 x 0.002 in)

Blacklight

LED

Electrical input and output

Number & Type

banana-plug inputs for electrical parameters, resistance thermometers and thermocouples

Resistance thermometer (RTD)

Pt100 (385, 3616, 3906, 3926, 3923), Pt200, Pt500, Pt1000 (385, 3916), Ni100, Ni120, Cu10, Cu100

Thermocouple

Types J, K, T, F, R, S, B, U, L, N, E, C

Voltage Signal

input: DC ±100 mV, ±2 V, ±80 V
output: DC 20 V

Current Output

input: DC ±100 mA
output: DC 20 mA

Frequency Signal

0 ... 50,000 Hz

Pulses Signal

1 ... 999,999

Resistance

0 ... 10,000 ?

Voltage Supply

DC 24 V

HART® communication

HART Module

based on HART® universal and common practice commands

Resistance

HART® resistance 250 ? (activatable)

Loop Current

max. DC 24 mA

Voltage Supply

DC 24 V

Pressure connection

1/8 BSP (female)

Permissible media

clean, dry, non-corrosive gases

Temperature compensation

-10 … +50 °C (14 ... 122 °F)

Temperature coefficient

0.001 % of reading/°C, outside of 19 ... 23 °C (66 ... 73 °F)

Best Instrument

Units

bar, mbar, psi, psf, Pa, hPa, kPa, MPa, torr, atm, kg/cm?2;, kg/m?2;, mmHg (0 °C), cmHg (0 °C), mHg (0 °C), inHg (0 °C), mmH2O (4 °C), cmH2O (4 °C), mH2O (4 °C), inH2O (4 °C), ftH2O (4 °C)

Voltage Supply

Battery Type

rechargeable battery NiMH

Battery life (fully-charged)

8 hours for typical usage

Power Supply

AC 100 ... 240 V, 50/60 Hz

Permissible ambient conditions

Operating Temperature

-10 ... +50 °C (14 ... 122 °F)

Storage Temperature

-30 ... +80 °C (-22 ... +176 °F)

Relative Humadity

Operating humidity: 10 ... 90 % r. h. (non-condensing) Storage humidity: 0 ... 90 % r. h. (non-condensing)

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.