Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

WIKA

CTD9300- 650 -- Temperature Dry-Well Calibrator

Category: TEMPERATURE, CALIBRATORS

Model: Dry Block Calibrator , Dry Block Calibrators

Avaibility: AVAILABLE

Call For Price

Range of applications

Whether in laboratories, workshops or on site, these temper-ature dry-well calibrators can meet any calibration require-ment. As an option, all instruments are available with an integrated measuring instrument. This enables the measure-ment of resistances, thermoelectric voltages and also current signals (from thermometers with a 0/4 ... 20 mA transmitter) and their direct display in °C.

Using our calibration software and a laptop computer, fully automatic calibrations of electrical thermometers can be carried out anywhere. It is also possible to retrofit the integra-ble measuring instrument into existing calibrators.

Two models from -35 ... +650 °C (-31 ... +1,202 °F) The temperature dry-well calibrators are available for two temperature ranges. The model CTD9300-165 is for temper-atures ranging from -35 ... +165 °C (-31 ... +329 °F) and is primarily suitable for biotechnology, pharmaceutical and food industry applications. Above 40 °C (104 °F), there is the model CTD9300-650 for temperatures up to 650 °C (1,202 °F).

This model is mainly used in power plants, plant construction and also the chemical industry. All instruments are fitted with blocks for large inserts, of 28 mm diameter by 150 mm long (1.1 x 5.91 in).

Calibration; simple, quick and reliable We know our customers' requirements well: Nowadays the main features required are not only high reliability and accuracy, but also safe and simple operation. Our temperature dry-well calibrators work with metal blocks that are cooled and heated electrically. Inserts with different inner diameters enable calibration of test items with a range of diameters.

The calibration instruments of the CTD9300 series achieve the temperature set point extremely quickly, thanks to a controller developed by us specifically for calibration tasks, thus helping to save costs.

Specifications

CTD9300-650

CTD9300-165

Display

Temperature range

40 ... 650 °C (104 ... 1,202 °F)

-35 ... +165 °C (-31 ... +329 °F)

Accuracy 1)

±0.3 K at 300 °C (572 °F)

±0.1 K at -30 °C (-22 °F)

±0.6 K at 650 °C (1,202 °F)

±0.16 K at 165 °C (329 °F)

Stability 2)

±0.03 K at 100 °C (212 °F)

±0.01 to 0.02 at 165 °C (329 °F)

±0.09 K at 650 °C (1,202 °F)

Resolution

0.01 K

Temperature distribution

Axial homogeneity 3)

0.4 K

0.06 K

Radial homogeneity 4)

dependent on temperature, temperature probes and their quantity

Temperature control

Heating time

30 min from 20 °C to 650 °C

12 min from 20 °C to 165 °C

(from 68 °F to 1,202 °F)

(from 68 °F to 329 °F)

Cooling time

80 min from 650 °C to 100 °C

7 min from +20 °C to -20 °C

(from 1,202 °F to 212 °F)

(from +68 °F to -4 °F)

Stabilisation time 5)

dependent on temperature and temperature probe

Metal block

Insertion depth

150 mm (5.91 in)

150 mm (5.91 in)

Insert dimensions

Ø 28 x 150 mm (1.1 x 5.91 in)

Ø 28 x 150 mm (1.1 x 5.91 in)

Block material

Brass

Aluminium

Voltage supply

Power supply 6)

AC 230 (115) V, 50/60 Hz

AC 100 ... 240 V, 50/60 Hz

Power consumption

1,000 W

400 W

Power cord

for Europe, 230 V

Communication

Interface

RS-232

RS-232

Case

Dimensions (W x D x H)

160 x 320 x 420 mm (6.3 x 12.6 x 16.54 in)

160 x 320 x 420 mm (6.3 x 12.6 x 16.54 in)

Weight

10 kg (22.1 lbs)

10 kg (22.1 lbs)

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.