The Element CO2 is a wireless data logger that measures and records carbon dioxide, humidity, and temperature levels in a variety of growing applications. This data logger is ideal for use in air quality studies including HVAC studies, as well as day to day monitoring of plant growing cycles.
The Element CO2 data logger comes with a 16 foot cable connected to the CO sensor, making it ideal for placement around various sized grow rooms to ensure consistent, optimum levels. The logger features an LCD screen which provides instant access to current readings, as well as minimum, maximum, and average statistics.
The device also features configurable alarms, battery life indicator, and the ability to reset statistics without impacting the data collection. The logger features a convenient wall mount, while the CO2 sensor is equipped with dual lock for easy and secure placement and effortless mobility.
Temperature recorded on the Element CO2 can be expressed in °C, °F, °R, or K while humidity can be shown in %RH, mg/ml, and Dew Point. Carbon dioxide can be expressed as either ppm or as a percentage. All units can be viewed on both the LCD screen as well as in the software.
By determining the levels of carbon dioxide, improvements can be made to the ventilation systems and optimum grow environments can be ensured. The Element CO2 can be used as a standalone data logger, or used wirelessly to transmit collected data back to a central PC for real time monitoring. Cloud monitoring is also possible with MadgeTech Cloud Services.
The Element CO2 can be used as a single wireless data logging system, or can be expanded to a large scale system including hundreds of data loggers. The Element CO2 utilizes the latest version of the MadgeTech 4 Data Logger Software to analyze data or generate reports in graphs or tabular formats. Summary and statistic views are also available for further analysis, as well as the capability to export to Excel®.
Carbon Dioxide (CO2)
Measurement Range:
|
0 ppm to 200,000 ppm |
Measurement Resolution:
|
10 ppm |
CalibratedAccuracy: |
±70 ppm
|
Sensor Warm Up Time: |
30 seconds
|
Temperature
Measurement Range: |
0 °C to +55 °C (+32 °F to +131 °F) |
|
|
|
|
Measurement |
0.08 °C |
|
Resolution: |
||
|
||
|
|
|
Calibrated Accuracy: |
±1 °C |
|
Humidity
Measurement Range: |
0 %RH to 95 %RH |
|
|
|
|
Measurement |
0.08 %RH |
|
Resolution: |
||
|
||
|
|
|
Calibrated Accuracy: |
±3 %RH from 25 %RH to 75 %RH @ 25 °C, 7 %RH otherwise |
|
|
|
General
Reading Rate: |
1 reading every second up to 1 reading every 24 hours |
|
|
|
|
Memory: |
10,752 readings per channel |
|
|
|
|
|
• Green LED blinks every 5 seconds to indicate unit is logging |
|
LED Functionality: |
• Blue LED blinks every 15 seconds to indicate unit is in wireless |
|
mode |
||
|
||
|
• Red LED blinks every 1 second to indicate alarm condition |
|
|
|
|
Memory Wrap Around: |
Yes |
|
|
|
|
Start Modes: |
Immediate Start & Delayed Start |
|
|
|
|
Battery Type: |
Ultralife 9V Lithium included; user replaceable |
|
|
|
|
Battery Life: |
Approximately 16 months typical at a 10 minute reading rate |
|
|
|
|
Approvals: |
US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), |
|
Japan (LCIE) |
||
|
||
|
|
|
Time Accuracy: |
±1 minute/month @ 25 °C |
|
|
|
Computer |
USB to mini USB, 250,000 baud for standalone operation or RFC1000/ |
|
Interface: |
RFC1000-CE/RFC1000-IP69K required for wireless operation |
|
|
|
|
Operating System |
XP SP3/Vista/Windows 7/Windows 8 |
|
Compatibility: |
||
|
||
|
|
|
MadgeTech Software |
• Standard Software version 4.2.1.1 or later |
|
Compatibility |
• Secure Software version 4.2.0.1 or later |
|
|
|
|
Operating |
• 0 °C to +55 °C (+32 °F to +131 °F) |
|
• 0 %RH to 95 %RH non-condensing |
||
Environment: |
||
• 0.002 PSIA to 100 PSIA |
||
|
||
|
|
|
|
• Data logger: 3.0 in x 3.5 in x 0.95 in |
|
Dimensions: |
(76.2 mm x 88.9 mm x 24.1 mm) |
|
• Sensor: 1.98 in x 1.98 in x 1.15 in |
||
|
(50.3 mm x 50.3 mm x 29.2 mm) |
|
|
• Cable Length: 16 ft (192 in) |
|
|
|
|
Weight |
140 g (4.9 oz) |
|
|
|
|
Enclosure Material: |
ABS Plastic |
|
|
|
|
|
User configurable audible, on-screen, email and text (SMS) alarms. |
|
Alarm: |
Alarm Delay: A cumulative alarm delay may be set in which the device |
|
|
will activate the alarm (via LED) only when the device has recorded a user |
|
|
specified time duration of data. |
|
|
|
|
Audible Alarm |
1 Beep per second for reading alarm above/below threshold |
|
Functionality: |
||
|
||
Wireless
RF Frequency: |
2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver |
||
with fully bi-directional communication |
|||
|
|||
|
|
||
Band: |
ISM band 2.405-2.475 GHz Operation (channels 11 through 25) |
||
@ 250 kbps data rate |
|||
|
|||
|
|
|
|
Transceiver |
-95 dBm typical |
||
Sensitivity: (RFC1000) |
|||
|
|
||
|
|
|
|
Transmission |
• |
RFC1000, RFC1000-CE & RFC1000-IP69K |
|
Distance: |
|
2,000 ft max. outdoors - line of sight unobstructed |
|
(to data loggers) |
|
500 ft max. indoors - typical urban environment |
|
|
|
|
|
|
• |
RFC1000 |
|
|
|
4,000 ft max. outdoors - line of sight unobstructed |
|
Transmission |
|
1,000 ft max. indoors - typical urban environment |
|
• RFC1000-CE |
|||
Distance: |
|
2,500 ft max. outdoors - line of sight unobstructed |
|
(to other RFC1000’s) |
|
700 ft max. indoors - typical urban environment |
|
|
• |
RFC1000-IP69K |
|
|
|
4,000 ft max. outdoors - line of sight unobstructed |
|
|
|
1,000 ft max. indoors - typical urban environment |
|