Element HT -- Wireless Humidity & Temperature Data Logger

Category: DATA LOGGER, TEMPERATURE, HUMIDITY

Model: Humidity, Temperature, Wireless, Humidity Data Logger

Avaibility: AVAILABLE

Call For Price

The Element HT is a wireless temperature and humidity data logger with digital display. The Element HT is ideal for both HVAC studies and everyday temperature and humidity monitoring in both grow and storage rooms. Designed with external humidity and RTD

based temperature sensors, the device provides a fast response time for both parameters. For customer convenience, functions include starting, stopping and downloading from the device wirelessly from a PC with the use of an RFC1000. This allows customers to quickly access data and spend less time maintaining the device. Data can be provided in

real time back to a central PC, or the device may be downloaded at periodic intervals. For real time monitoring on the go, simply connect the Element HT to MadgeTech Cloud Services, allowing data tobe accessed from any internet enabled device. The digital display provides the current reading for both the humidity and temperature channels with minimum, maximum and average statistics accessible for a quick snapshot of the logged data. The Element HT features user programmable alarm settings for both temperature and humidity parameters. An audible buzzer and LED alarm indicator notifies users when the temperature or humidity is above or below the threshold set in the alarm. This allows growers to take action faster, saving plants, time and money. Email and text alarms can also be configured and sent from within the software, allowing users to be notified almost anywhere.The Element HT can be used as a single, wireless data logging system, or it can be expanded to a large scale system, which can include hundreds of data loggers measuring a number of areas (additional MadgeTech wireless data loggers

and transceivers may be required). The Element HT utilizes the latest MadgeTech Software, version 4.1. MadgeTech Data Logger Software is a powerful, analytic tool. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.

Temperature

Internal Channel Temperature Range:

-20 °C to +60 °C (-4 °F to +140 °F)

Temperature Resolution:

0.01 °C (0.02 °F)

Calibrated Accuracy:

±0.5 °C/± 0.9 °F (0 °C to +55 °C/32 °F to 131 °F)

Response Time:

10 minutes free air

Humidity

Humidity Range:

0 to 95 %RH

Humidity Resolution:

0.1 %RH

Humidity Calibrated Accuracy:

±3.0 %RH, ±2.0 %RH typical @ 25 °C (10 %RH to 90 %RH; 5 °C to 55 °C)

Response Time:

2 minutes to 63% of change

Wireless

RF Frequency:

2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication

Band:

ISM band 2.405-2.48 GHz

Maximum Output Power:

+0 dBm typical

Receiver Sensitivity (RFC1000):

-95 dBm typical

Transmission Distance (to data loggers)

• RFC1000, RFC1000-CE & RFC1000-IP69K 2,000 ft max. outdoors - line of sight unobstructed 500 ft max. indoors - typical urban environment

Transmission Distance (to other RFC1000’s)

• RFC1000

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

• RFC1000-CE

2,500 ft max. outdoors - line of sight unobstructed

700 ft max. indoors - typical urban environment

• RFC1000-IP69K

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

General

Reading Rate:

1 reading every second up to 1 reading every 24 hours

Memory:

16,128 per channel

LED Functionality:

• Green LED blinks every 5 seconds to indicate unit is logging

• Blue LED blinks every 15 seconds to indicate unit is in wireless mode

• Red LED blinks every 1 second to indicate alarm condition

Wrap Around:

Yes

Start Modes:

Immediate Start

Calibration:

Digital calibration through software

Calibration Date:

Automatically recorded within device

Battery Type:

9V lithium battery included; user replaceable

Battery Life:

3 years typical at 1 minute reading rate

Data Format:

• For Display: °C or °F, %RH

• For Software: Date and time stamped °C, K, °F, or °R, %RH, mg/ mL, Dew Point - °C/K/°F/°R

Time Accuracy:

± 1 minute/month

Computer Interface:

USB to mini USB, 250,000 baud for standalone operation or RFC1000

required for wireless operation

Software:

XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only)

Operating Environment:

20 °C to +60 °C (-4 °F to +140 °F) 0 %RH to 95 %RH non-condensing

Dimensions:

3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) Data logger only

Enclosure Material:

ABS Plastic

Approvals:

US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)

Alarm:

Programmable high and low limits for temperature and humidity.

Alarm is activated when temperature or humidity reaches or exceeds set limits.

A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.

Audible Alarm Functionality:

1 beep per second for reading alarm above/below threshold

BATTERY WARNING: Battery may leak, flame or explode if disassembled, shorted, charged, connected together, mixed with used or other batteries, exposed to fire or high temperature. Discard used battery promptly. Keep out of reach of children.