Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

MADGETECH

RFC02 RHTemp 2000A -- Wireless CO, Humidity and Temperature Data Logger

Category: DATA LOGGER

Model: Carbon Dioxide

Avaibility: AVAILABLE

Call For Price

The RFCO2RHTemp2000A is a wireless data logger that measures and records carbon dioxide, humidity, and temperature levels in a variety of applications. This data logger is ideal for use in air quality studies including HVAC applications and much more. The RFCO2RHTemp2000A data logger comes with a 16 ft cable connected to the CO2 sensor, making it ideal for placement within enclosed environments such as an incubator to ensure optimum levels. The logger features an LCD screen which provides instant access to current readings, as well as minimum, maximum, and average statistics. The device also features configurable alarms, battery life indicator, and the ability to reset statistics without impacting the data collection. The logger features a convenient wall mount, while the CO2 sensor is equipped with dual lock for easy and secure placement and effortless mobility. Temperature recorded on the RFCO2RHTemp2000A can be expressed in °C, °F, °R, or K while humidity can be shown in %RH, mg/ml, and Dew Point. Carbon dioxide can be expressed as either ppm or as a percentage. All units can be viewed on both the LCD screen as well as in the software. The device can be used to determine ventilation efficiency in a variety of environments including buildings, offices, hospitals, schools, and laboratories. By determining the levels of carbon dioxide, improvements can be made to the ventilation systems and energy saving opportunities become more easily identified. The RFCO2RHTemp2000A can be used as a standalone data logger, or may used wirelessly to transmit collected data back to a central PC for real time monitoring. The RFCO2RHTemp2000A can be used as a single wireless data logging system, or can be expanded to a large scale system including hundreds of data loggers. The RFCO2RHTemp2000A utilizes the latest version of the MadgeTech 4 Data Logger Software to analyze data or generate reports in graphs or tabular formats. Summary and statistic views are also available for further analysis, as well as the capability to export to Excel.

Carbon Dioxide (CO2)

Measurement Range

0 ppm to 200,000 ppm

Measurement Resolution

100 ppm

Calibrate Accuracy

± 70 ppm

Sensor Warm up Time

30 seconds

Temperature

Measurement Range

0 °C to +55 °C (+32 °F to +131 °F)

Measurement Resolution

0.08 °C

Calibrate Accuracy

± 1°C

Humadity

Measurement Range

0 %RH to 95 %RH

Measurement Resolution

0.08 %RH

Calibrate Accuracy

±3 %RH from 25 %RH to 75 %RH @ 25 °C, 7 %RH otherwise

General

Reading Rate

1 reading every second up to 1 reading every 24 hours

Memory

10,752 readings per channel

LED Functionality

•Green LED blinks every 5 seconds to indicate unit is logging

•Blue LED blinks every 15 seconds to indicate unit is in wireless mode

•Red LED blinks every 1 second to indicate alarm condition

Memory Warp Around

Yes

Start Modes

Immediate Start & Delayed Start

Battery Type

Ultralife 9V Lithium included; user replaceable

Battery Life

Approximately 16 months typical at a 10 minute reading rate

Approval

US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)

Time Accuracy

±1 minute/month @ 25°C

Computer Interface

USB to mini USB, 250,000 baud for standalone operation or RFC1000/RFC1000-CE/RFC1000-IP69K required for wireless operation

Operating System Compatibility

XP SP3/Vista/Windows 7/Windows 8

Madgetech Software Compatibility

  • Standard Software version 4.2.1.1 or later
  • Secure Software version 4.2.0.1 or later

Operating Environment

  • 0 °C to +55 °C (+32 °F to +131 °F)
  • 0 %RH to 95 %RH non-condensing
  • 0.002 PSIA to 100 PSIA

Dimension

  • Data logger: 3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm)
  • Sensor: 1.98 in x 1.98 in x 1.15 in (50.3 mm x 50.3 mm x 29.2 mm)
  • Cable Length: 16 ft (192 in)

Weight

140 g (4.9 oz

Enclosure Material

ABS Plastic

Alarm

User configurable audible, on-screen, email and text (SMS) alarms.

Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data

Audible Alarm Functionality

1 Beep per second for reading alarm above/below threshold

Wireless

RF Frequency

2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication

Band

ISM band 2.405-2.475 GHz Operation (channels 11 through 25) @ 250 kbps data rate

Transceiver Sensitivity: (RFC1000)

-95 dBm typical

Transmission Distance:

(to data loggers)

RFC1000, RFC1000-CE & RFC1000-IP69K 2,000 ft max. outdoors - line of sight unobstructed 500 ft max. indoors - typical urban environment

Transmission Distance:

(to other RFC1000’s)

• RFC1000

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

•RFC1000-CE

2,500 ft max. outdoors - line of sight unobstructed

700 ft max. indoors - typical urban environment

•RFC1000-IP69K

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.