Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

WIKA

CTR6000 -- DC Resistance Thermometry Bridge

Category: TEMPERATURE, CALIBRATORS

Model: Temperature Standard, Temperature Standards

Avaibility: AVAILABLE

Call For Price

The model CTR6000 resistance thermometry bridge is a high-performance DC resistance thermometry bridge. The CTR6000 provides the latest technology in DC measurement. This way of measurement has always been a hallmark of ASL instruments and the CTR6000 continues that tradition.

The CTR6000 series features a large graphic display, combining versatility with ease of use. As well as the flexible menu options on the display, the CTR6000 also includes buttons dedicated to select common functions. For multi-channel applications, the CTR6000 can be used with ASL's switch box systems CTS9000.

Data can be recorded and stored on a PC through the ULog temperature measurement and data acquisition software. The DC version provides a switched DC sensor current to simulate the advantages of AC measurement. In addition to measuring platinum resistance thermometers (PRTs), the CTR6000 also measures NTC thermistors.

Specifications

Model CTR6000

Input channels

2 on the main device (one platinum resistance thermometer (PRT) or thermistor + one reference

resistor)

60 over multiplexer CTS9000

Input connections

4 x BNC + shield (front panel)

Data entry format

ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes

Steinhart and Hart for NTC thermistors

Measuring ranges

Sense current

10 µA, 20 µA, 100 µA, 200 µA, 1 mA, 2 mA, 10 mA

Sense current mulitpliers

0.5 and ?2

Temperature range

-200 ... +962 °C, depending on thermometer probe

Resistance range

0 … 500 k?

Internal resistors

Values

25 ?, 100 ?, 10 k?, 100 k?

Thermal stability

±0.1 ppm/°C

Accuracy

±0.01 % (uncalibrated)

Accuracy

PRT 1)

±3 ppm full range (ratio)

±3 ppm of reading or 0.0003 ? whichever greater (resistance)

±0.8 mK at 0 °C, ±3 mK full range (temperature)

Thermistor

0 ... 10 k? ±10 ppm of reading or 0.01 ? (whichever value is greater)

10 ... 50 k?

±20 ppm of reading

50 ... 100 k?

±40 ppm of reading

100 ... 500 k?

±100 ppm of reading

Display

Screen

large graphic VFD display screen

Units

ratio, °C, °F, K or ?

Resolution

0.1 mK

Functions

Real-time clock

integrated clock with date

Voltage supply

Power supply

AC 90 ... 264 V, 47 ... 63 Hz; universal rear input on rear panel

Power consumption

max. 95 VA

Permissible ambient conditions

Operating temperature

15 ... 25 °C

Storage temperature

-20 ... +50 °C

Communication

Interface

USB, RS-232 or IEEE

Case

Dimensions

455 x 150 x 450 mm (W x H x D)

Weight

7 kg

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.