Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

WIKA

CTR6500 -- AC Resistance Thermometry Bridge

Category: TEMPERATURE, CALIBRATORS

Model: Temperature Standard, Temperature Standards

Avaibility: AVAILABLE

Call For Price

The performance of the model CTR6500 resistance thermometry bridge is improved significantly by using the proven AC bridge technology. Due to the elimination of thermal EMF errors and the automatic cancellation of probe and cable reactance effects, the CTR6500 provides excep-tional stability with time and ambient temperature and has an excellent resolution thanks to inherently low noise.

These make the CTR6500 perfectly suited to high-accuracy temperature measurement and calibration. The CTR6500 has 25 ? and 100 ? internal standard resistors and can also be used with external standard resistors. It has a ratio range of 0 ... 4.9999999 or 0 ... 500 ? resistance and is capable of measuring temperature ranges to meet ITS 90, CVD and EN 60751 standards.

The results are shown on the large-scale, multi-function VFD screen. The mean, min and max value, standard deviation and the sampling rate can also be displayed with a separate graphical display. To ensure the long-term reliability the CTR6500 uses surface mount technology with no mechani-cal relays.

Specifications

Model CTR6500

Probe types

Industrial platinum resistance thermometers (PRTs) and standard platinum resistance

thermometers (SPRTs) with Ro = 25 ? and 100 ? up to an alpha of 0.00392

Input channels

2 on the main device (one PRT, SPRT or resistor + one reference resistor)

60 over multiplexer CTS9000

Input connections

4 x BNC + shield (front panel)

Data entry format

ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes

Measuring ranges

Sense current

100 µA, 200 µA, 500 µA, 1 mA, 2 mA, 5 mA, 10 mA

Sense current mulitpliers

x ?2

Temperature range

-200 ... +962 °C, depending on thermometer probe

Resistance range

0 … 500 ?

Internal resistors

Values

25 ?, 100 ?

Thermal stability TCR

±0.1 ppm/°C

Accuracy

±0.01 % (uncalibrated)

Accuracy 1)

Ratio range 0 ... 1 accuracy 0.4 ppm equivalent to 0.1 mK at 0 °C

Ratio range 1 ... 2 accuracy 0.6 ppm equivalent to 0.3 mK full range

Ratio range 2 ... 3 accuracy 0.8 ppm equivalent to 0.8 mK full range

Ratio range 3 ... 5 accuracy 1 ppm equivalent to 1.25 mK full range

Display

Screen

large graphic VFD display screen (adjustable brightness)

Units

Ratio, °C, °F, K or ?

Resolution

0.1 ppm

0.01 mK

0.001 m?

Functions

Real-time clock

integrated clock with date

Voltage supply

Power supply

AC 90 ... 264 V, 47 ... 63 Hz; universal rear input on rear panel

Power consumption

max. 95 VA

Permissible ambient conditions

Operating temperature

15 ... 25 °C

Storage temperature

-20 ... +50 °C

Communication

Interface

USB, RS-232 or IEEE-488.2

Case

Dimensions

455 x 150 x 450 mm (W x H x D)

Weight

9 kg

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.