VTMS -- Vaccine Temperature Monitoring System

Category: TEMPERATURE

Model: Temperature Data Logger

Avaibility: AVAILABLE

Call For Price

MadgeTech’s Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measure-ment and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes an NIST traceable RFTCTemp2000A data logger with thermocouple and Glycol bottle. Additionally, the RFTCTemp2000A data logger in the VTMS system has a convenient LCD to ensure temperature parameters are met, in real time. Starting, stopping and downloading from the device are all performed wirelessly using the RFC1000 wireless transceiver. The current reading, minimum, maximum and average statistics can all be obtained through the display.

The convenient digital display provides the current reading for the thermocouple channel. Minimum, maximum and average statistics are also provided for a convenient snap shot of the logged data. For instant, out of range notification, an audible buzzer as well as LED alarm indicator notifies users when the temperature is above or below the user specified alarm. The RFTCTemp2000A also features programmable trigger settings for applications in which temperature logging is critical only above or below a certain temperature.

The VTMS can alert the user, or other personnel, via e-mail or text message if the refrigerator has failed, or if the temperature is outside of the nominal range. This allows users to take immediate actions to ensure vaccines and pharmaceuticals in storage are not destroyed. To prevent false alarms, the RFTCTemp2000A is connected to a Glycol bottle which provides temperature buffered readings. The VTMS utilizes the new MadgeTech 4.0 Software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.

Remote Channel

Thermocouple

Connection:

Female subminiature (SMP) (MP model) Pluggable screw terminal (TB model)

Cold Junction Compensation:

Automatic based on internal channel

Max. Thermocouple Resistance:

100 ?

Thermocouple Type :

Range (°C)

Resolution

Accuracy

J

-210 to +760

0.1 °C

±0.5 °C

K

-270 to +1370

0.1 °C

±0.5 °C

T

-270 to +400

0.1 °C

±0.5 °C

E

-270 to +980

0.1 °C

±0.5 °C

R

-50 to +1760

0.5 °C

±2.0 °C

S

-50 to +1760

0.5 °C

±2.0 °C

B

+50 to +1820

0.5 °C

±2.0 °C

N

-270 to +1300

0.1 °C

±0.5 °C

Thermocouple accuracy is specified with a 24 AWG

*Response Time:

? = 2 minutes to 63% of change

Wireless

RF Frequency:

2.45 GHz IEEE 802.15.4 ultra-low

power wireless transceiver with fully

bi-directional communication

Band:

ISM band 2.405-2.48 GHz

Maximum Output Power:

+0 dBm typical

Receiver Sensitivity (RFC1000):

-95 dBm typical

Transmission Distance (to data loggers)

• RFC1000, RFC1000-CE & RFC1000-IP69K

2,000 ft max. outdoors - line of sight unobstructed 500 ft max. indoors - typical urban environment

Transmission Distance (to other RFC1000’s)

  • RFC1000

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

  • RFC1000-CE

2,500 ft max. outdoors - line of sight unobstructed 700 ft max.

Indoors - typical urban environment

  • RFC1000-IP69K

4,000 ft max. outdoors - line of sight unobstructed

1,000 ft max. indoors - typical urban environment

General

Reading Rate:

1 reading every second up to 1 reading every 24 hours

Memory:

16,128 per channel

LED Functionality:

Green LED blinks every 5 seconds to indicate unit is logging

Blue LED blinks every 15 seconds to indicate unit is in wireless mode

Red LED blinks every 1 second to indicate alarm condition

Wrap Around:

Yes

Start Modes:

Immediate Start

Calibration:

Digital calibration through software

Calibration Date:

Automatically recorded within device

Battery Type:

9V lithium battery included;

user replaceable

Battery Life:

3 years typical at 1 minute reading rate

• For Display: °C or °F

Data Format:

• For Software: Date and time stamped

°C, K, °F, or °R

Time Accuracy:

± 1 minute/month

Computer

USB to mini USB, 250,000 baud for

standalone operation or RFC1000

Interface:

required for wireless operation

Software:

XP SP3/Vista/Windows 7/Windows 8

(MadgeTech 4 only)

Operating

-20 °C to +60 °C (-4 °F to +140 °F)

Environment:

0 %RH to 95 %RH non-condensing

3.0 in x 3.5 in x 0.95 in

Dimensions:

(76.2 mm x 88.9 mm x 24.1 mm)

Data logger only

Enclosure Material:

ABS Plastic

Programmable high and low limits;

alarm is activated when temperature

reaches or exceeds sets limits.

Alarm:

Alarm Delay: A cumulative alarm delay

may be set in which the device will

activate the alarm (via LED) only when

the device has recorded a user specified

time duration of data.

Audible Alarm

1 Beep per second for reading alarm

Functionality:

above/below threshold

Approvals:

US (FCC), CA (IC), CE, South Korea

(KCC), China (CMIIT), Japan (LCIE)