PRTC110 -- Differential Pressure and Thermocouple Temperature Recorder
Category: DATA LOGGER, PRESSURE
Model: Pressure, Pressure Data Logger
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
PRTC110 -- Differential Pressure and Thermocouple Temperature Recorder
Category: DATA LOGGER, PRESSURE
Model: Pressure, Pressure Data Logger
Avaibility: AVAILABLE
Call For Price
The PRTC110 is a differential pressure and temperature data logger, ideal for use in factory and laboratory applications. The device is available in a 0 to 2inH2O or 0 to 5inH2O model.
The PRTC110 features a real-time clock module that extends the battery life up to 5 years and allows for high speed downloads. This device will measure and record up to 10,922 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The PRTC110 can be started and stopped directly from your computer and its small size allows it to fit almost anywhere.
The PRTC110 makes data retrieval quick and easy. Simply plug the device into an empty COM or USB port and our user-friendly software does the rest.
Internal Chanel
Temperator Range |
-20 ºC to +80 ºC (-4 ºF to +176 ºF) |
|
Temperatur Resolution |
0.1 ºC (0.18 ºF) |
|
Calibrated Accuracy |
|
Remote Chanel
Thermocouple Types |
|
||
Thermocouple Connection |
Mini U connector |
||
Cold Junction Compensation |
Automatic, based on internal channel |
||
Maximum thermocouple Resistance: |
1000 ?, <1000> |
||
**Thermocouple Type |
Range (ºC) |
Resolution |
Accuracy |
J |
-210 to +760 |
0.1 ºC |
±0.5 ºC |
K |
-270 to +1370 |
0.1 ºC |
±0.5 ºC |
T |
-270 to +400 |
0.1 ºC |
±0.5 ºC |
E |
-270 to +980 |
0.1 ºC |
±0.5 ºC |
R |
-50 to +1760 |
0.1 ºC |
±0.5 ºC |
S |
-50 to +1760 |
0.1 ºC |
±0.5 ºC |
B |
+50 to +1820 |
0.1 ºC |
±0.5 ºC |
N |
-270 to +1300 |
0.1 ºC |
±0.5 ºC |
Voltage |
-75 mV to +75 mV |
5 ?V |
±20 ?V |
**Accuracy specifications based on 3-meter 24 AWG thermocouple. |
|||
Pressure Range (nominal) |
0 to 2 inH2O and 0 to 5 inH2O (differential) |
||
Pressure Range (Max) |
-2 to +4inH2O and –2 to +8inH2O (differential) |
||
Pressure Resolution |
0.002 inH2O and 0.005 inH2O |
||
Pressure Specified Accuracy |
Nominal Range at +25 ºC (+77 ºF) |
||
Combined Calibration Accuracy |
±5.0% FSR max at 25 ºC over 1 year |
||
Start Modes |
Software programmable immediate start or delay start up to six months in advance |
||
Real Time Recording |
May be used with PC to monitor and record data in real time |
||
Memory |
10,922 readings per channel; software configurable memory wrap |
||
Reading Rate |
2 seconds to 24 hours, selectable in software |
||
Calibration |
Digital calibration through software |
||
Calibration Date |
Automatically recorded within device |
||
Battery Type |
3.6V lithium battery included, user replaceable |
||
Battery Life |
5 year typical (5 minute, 25 ºC) |
||
Data Format |
Date and time stamped ºC, ºF, ºK, ºR; inH2O, PSIG, inHg, mmHg, bar, atm, Torr, Pa, kPa, MPa |
||
Time Accuracy |
±1 minute/month (at 20 ºC to 30 ºC) |
||
Computer Interface |
PC serial or USB (interface cable required); 57,600 baud |
||
Software |
XP SP3/Vista/Windows 7/Windows 8 |
||
Operating Environment |
-20 ºC to +80 ºC (-4 ºF to +176 ºF), 0 %RH to 95 %RH non-condensing |
||
Dimensions |
2.7 in x 1.6 in x 0.8 in (68 mm x 41 mm x 20 mm) plus connective tubing |
||
Weight |
1.25 oz (34 g) |
||
Enclosure |
ABS Plastic |
||
Approvals |
CE |
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT RECHARGE, DISASSEMBLE, HEAT ABOVE 212 °F, INCINERATE OR EXPOSE CONTENTS TO WATER
OTHER PRODUCT