Product Notes
How it Works
Once the logger is started samples are taken on each axis (X, Y and Z) every 1024Hz (1 ms). These samples are compared with the trigger values and if it crosses the threshold value then it records the timestamp and starts logging the triggered data. If the samples are not above the threshold value then it is logged as the pre-trigger data. Since only 50 pre-trigger values can be recorded the data gets overwritten if the logger is not triggered within 50 pre-trigger values.
The sampling frequency is the same for all reading rates therefore the samples are skipped based on the reading rate. For example: if the reading rate is 512Hz the samples are taken every 1ms but every other sample gets logged instead of logging every sample.
Trigger Settings
Below is a table of default trigger values based on the range of the logger. All axis are enabled to check for triggers at these g levels.
|
Range |
5 g |
50 g |
100 g |
250 g |
|
|
|
|
|
|
|
Trigger Value |
2.5 g |
25 g |
52.5 g |
120 g |
|
|
|
|
|
|
To edit trigger values, select Start Device from the Start Menu. Click Yes, then select Trigger Settings. Click the Change button. Each axis can be set to trigger at a certain g force level. Check the Enable Trigger box to enable the trigger for that axis. The values can be typed in manually or configured by using the slider control. Click Save to save the changes. To initiate the TSR101 to constantly sample, set the high and low trigger settings to 0 g.
Axis Orientation
When the TSR101 is laying flat, with the label facing up, the x-axis indicates left to right direction and will read ~0 g when still. The y-axis reads in a top to bottom direction and reads ~0 g when still. The z-axis reads perpendicular to the other two axis, and will read ~1 g when still.
Installation Guide
Installing the Interface cable
Insert the device into a USB port. The drivers will install automatically.
Installing the software
Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Wizard
Device Operation
Connecting and Starting the data logger
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
Device Maintenance
Battery Replacement
Materials:
3/32” HEX Driver (Allen Key)
Replacement Battery (U9VL-J)
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The TSR101 standard calibration is performed at 0 g for the X-axis, 0 g for the Y-axis and 1 g for the Z-axis.
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
|
Description |
TSR101 |
|
|
|
|
Acceleration Sensor |
Shock (3 axes) |
|
|
|
|
Accelerometer Type |
MEMS Semiconductor |
|
|
|
|
Acceleration Range |
|
|
|
|
|
Acceleration Resolution |
*See Table for Details |
|
|
|
|
Calibrated Accuracy |
|
|
|
|
|
Memory |
349,471/channel |
|
|
|
|
Reading Rate |
1,024Hz to 1 second |
|
|
|
|
Frequency Response |
0Hz to approximately 400Hz (50, 100 g) |
|
|
|
|
Typical Battery Life |
7 days |
|
|
|
|
Required Interface Package |
IFC200 |
|
|
|
|
Baud Rate |
115,200 |
|
|
|
|
Operating Environment |
–20 °C to +60 °C, 0 to 95%RH (non-condensing) |
|
|
|
|
Dimensions |
3.5” x 4.4” x 1.0” (89 mm x 112 mm x 26 mm) |
|
|
|
|
Materials |
Anodized aluminum |
|
|
|
|
Weight |
12 oz (340 g) |
|
|
|
|
Approvals |
CE |
|
|
|
*TSR101 Acceleration Range, Resolution and Accuracy
|
Range (g) |
|
|
+ |
5 |
|
+ |
50 |
|
+ |
100 |
|
+ |
250 |
|||||||
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Resolution (g) |
0.01 |
0.05 |
0.1 |
0.2 |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accuracy (g) |
|
+ |
0.2 |
|
+ |
1 |
|
+ |
2 |
|
+ |
4 |
||||||||
|
|
|
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|