Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

WIKA

CTD9100- 450 -- Temperature Dry-Well Calibrator

Category: TEMPERATURE, CALIBRATORS

Model: Dry Block Calibrator , Dry Block Calibrators

Avaibility: AVAILABLE

Call For Price

Versatile in application

Nowadays, fast and simple testing of thermometers is a “must” when it comes to the operational safety of machines and plants.

The portable calibrators of the CTD9100 family are particularly suited for on-site calibrations and extremely user-friendly. Due to their compact design and their low weight, the instruments can be taken and used almost anywhere.

The new instrument concept brings together a stable heat source with precision Pt100 temperature measurement. This enables industrial temperature probes to be calibrated even more efficiently.

Regular monitoring of temperature probes helps to recognise failures promptly and shorten downtimes.

Easy to use

The temperature dry-well calibrators of the CTD9100 series work with temperature-controlled metal blocks and interchangeable inserts.

The calibration temperature, adjusted simply using two buttons on the controller, can be very quickly controlled. The actual and set temperature of the heating block can be displayed simultaneously on a large 4-digit, high-contrast LC display. Thus reading errors are virtually eliminated.

Thermometers with different diameters can be fitted into the calibrator using inserts, drilled to suit.

A new block design, with improved temperature homogeneity at the calibrator’s lower range, leads to smaller measurement uncertainties. The large insertion depth of 150 mm considerably reduces heat dissipation errors.

Model CTD9100-450

Temperature range from 40 ... 450 °C (104 ... 842 °F) The CTD9100-450 is used in the medium temperature range up to 450 °C (842 °F). It generates its temperature with resistive electrical heating and features an enlarged insert with Ø 60 mm (2.4 in). Thus, it is possible to calibrate several temperature probes simultaneously without the need of changing the insert.

Display

Model CTD9100-450

Model CTD9100-650

Temperature range

40 ... 450 °C (104 ... 842 °F)

40 ... 650 °C (104 ... 1,202 °F)

Accuracy 1)

0.3 ... 0.5 K

0.3 ... 0.8 K

Stability 2)

±0.05 K up to 100 °C (212 °F)

±0.05 K up to 100 °C (212 °F)

±0.1 K up to 450 °C (842 °F)

±0.1 K up to 600 °C (1,112 °F)

Resolution

0.01 up to 100 °C, then 0.1 (0.01 up to 212 °F, then 0.1)

Temperature distribution

Axial homogeneity 3)

dependent on temperature, temperature probes and their quantity

Radial homogeneity 4)

dependent on temperature, temperature probes and their quantity

Temperature control

Heating time

approx. 14 min from 20 to 450 °C

approx. 20 min from 20 to 600 °C

(from 68 °F to 842 °F)

(from 68 °F to 1,112 °F)

Cooling time

approx. 60 min from 450 to 100 °C

approx. 60 min from 600 to 100 °C

Stabilisation time 5)

(from 842 °F to 212 °F)

(from 1.112 °F to 212 °F)

dependent on temperature and temperature probe

Insert

Immersion depth

150 mm (5.91 in)

Insert dimensions

Ø 60 x 150 mm (2.36 x 5.91 in)

Ø 28 x 150 mm (1.1 x 5.91 in)

Insert material

Aluminium

Brass

Voltage supply

AC 230/240 V, 50/60 Hz 6)

Power supply

AC 230/240 V, 50/60 Hz

(AC 100 ... 240 V, 50/60 Hz) 7)

Power consumption

2.000 VA

1.000 VA

Fuse

10 A slow blow fuse

10 A slow blow fuse (at AC 110 V)

6.3 A slow blow fuse (at AC 230 V)

Power cord

AC 230 V; for Europe

Communication

Interface

RS-485

Case

Dimensions (W x D x H)

150 x 270 x 400 mm (5.91 x 10.63 x 15.75 in)

Weight

7,5 kg (16.5 lbs)

8 kg (17.6 lbs)

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.