CTD9100- 450 -- Temperature Dry-Well Calibrator
Category: TEMPERATURE, CALIBRATORS
Model: Dry Block Calibrator , Dry Block Calibrators
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
CTD9100- 450 -- Temperature Dry-Well Calibrator
Category: TEMPERATURE, CALIBRATORS
Model: Dry Block Calibrator , Dry Block Calibrators
Avaibility: AVAILABLE
Call For Price
Versatile in application
Nowadays, fast and simple testing of thermometers is a “must” when it comes to the operational safety of machines and plants.
The portable calibrators of the CTD9100 family are particularly suited for on-site calibrations and extremely user-friendly. Due to their compact design and their low weight, the instruments can be taken and used almost anywhere.
The new instrument concept brings together a stable heat source with precision Pt100 temperature measurement. This enables industrial temperature probes to be calibrated even more efficiently.
Regular monitoring of temperature probes helps to recognise failures promptly and shorten downtimes.
Easy to use
The temperature dry-well calibrators of the CTD9100 series work with temperature-controlled metal blocks and interchangeable inserts.
The calibration temperature, adjusted simply using two buttons on the controller, can be very quickly controlled. The actual and set temperature of the heating block can be displayed simultaneously on a large 4-digit, high-contrast LC display. Thus reading errors are virtually eliminated.
Thermometers with different diameters can be fitted into the calibrator using inserts, drilled to suit.
A new block design, with improved temperature homogeneity at the calibrator’s lower range, leads to smaller measurement uncertainties. The large insertion depth of 150 mm considerably reduces heat dissipation errors.
Model CTD9100-450
Temperature range from 40 ... 450 °C (104 ... 842 °F) The CTD9100-450 is used in the medium temperature range up to 450 °C (842 °F). It generates its temperature with resistive electrical heating and features an enlarged insert with Ø 60 mm (2.4 in). Thus, it is possible to calibrate several temperature probes simultaneously without the need of changing the insert.
Display |
Model CTD9100-450 |
Model CTD9100-650 |
|
|
|
Temperature range |
40 ... 450 °C (104 ... 842 °F) |
40 ... 650 °C (104 ... 1,202 °F) |
Accuracy 1) |
0.3 ... 0.5 K |
0.3 ... 0.8 K |
Stability 2) |
±0.05 K up to 100 °C (212 °F) |
±0.05 K up to 100 °C (212 °F) |
|
±0.1 K up to 450 °C (842 °F) |
±0.1 K up to 600 °C (1,112 °F) |
Resolution |
0.01 up to 100 °C, then 0.1 (0.01 up to 212 °F, then 0.1) |
|
Temperature distribution |
|
|
Axial homogeneity 3) |
dependent on temperature, temperature probes and their quantity |
|
Radial homogeneity 4) |
dependent on temperature, temperature probes and their quantity |
|
Temperature control |
|
|
Heating time |
approx. 14 min from 20 to 450 °C |
approx. 20 min from 20 to 600 °C |
|
(from 68 °F to 842 °F) |
(from 68 °F to 1,112 °F) |
Cooling time |
approx. 60 min from 450 to 100 °C |
approx. 60 min from 600 to 100 °C |
Stabilisation time 5) |
(from 842 °F to 212 °F) |
(from 1.112 °F to 212 °F) |
dependent on temperature and temperature probe |
|
|
Insert |
|
|
Immersion depth |
150 mm (5.91 in) |
|
Insert dimensions |
Ø 60 x 150 mm (2.36 x 5.91 in) |
Ø 28 x 150 mm (1.1 x 5.91 in) |
Insert material |
Aluminium |
Brass |
Voltage supply |
|
AC 230/240 V, 50/60 Hz 6) |
Power supply |
AC 230/240 V, 50/60 Hz |
|
|
|
(AC 100 ... 240 V, 50/60 Hz) 7) |
Power consumption |
2.000 VA |
1.000 VA |
Fuse |
10 A slow blow fuse |
10 A slow blow fuse (at AC 110 V) |
|
|
6.3 A slow blow fuse (at AC 230 V) |
Power cord |
AC 230 V; for Europe |
|
Communication |
|
|
Interface |
RS-485 |
|
Case |
|
|
Dimensions (W x D x H) |
150 x 270 x 400 mm (5.91 x 10.63 x 15.75 in) |
|
Weight |
7,5 kg (16.5 lbs) |
8 kg (17.6 lbs) |