CPH6210 -- Intrinsically Safe Hand-Held Pressure Indicator (Ex version)
Category: PRESSURE, CALIBRATORS
Model: Portable Calibrators, Portable Calibrator
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
CPH6210 -- Intrinsically Safe Hand-Held Pressure Indicator (Ex version)
Category: PRESSURE, CALIBRATORS
Model: Portable Calibrators, Portable Calibrator
Avaibility: AVAILABLE
Call For Price
Extensive application possibilities
Stainless steel pressure sensors with measuring ranges up to 1,000 bar (14,500 psi) are available for the model CPH62I0 hand-held pressure indicator. It is therefore particularly suitable as a test instrument for applications such as process engineering, chemical industry, refineries, etc. The digital indicator automatically detects the measuring range of the connected pressure sensor and guarantees a highly accurate pressure measurement.
Functionality
The CPH62I0 can be used for measuring both gauge and absolute pressure. Differential pressure measurement is possible with the 2-channel version CPH62I0-S2, and two connected model CPT62I0 reference pressure sensors. Selectable pressure units here are bar, mbar, psi, Pa, kPa, MPa, mmHg or inHg.
An integrated data logger and various other functions such as Min., Max., Hold, Tare, zero point adjustment, alarm, power-off, peak value detection (1,000 measurements/s), average value filter, etc. ensure that the CPH62I0 can be used for many different applications.
Software
In addition to the GSoft data logger evaluation software for the tabular and graphical representation of the logged data, WIKA-Cal calibration software for calibration tasks is also available. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. A USB interface is available for the data transfer.
Complete test and service cases
For maintenance and service applications, various case systems are available. These include service cases with or without pressure generation, battery, connection adapter, etc.
Certified accuracy
For each reference pressure sensor, the accuracy for the complete measuring chain is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a DKD/DAkkS calibration certificate for this instrument.
|
Measuring inputs |
1 input for CPH62I0-S1 |
|
|
|
|
|
|
|
|
|
|||
|
|
2 inputs for CPH62I0-S2 |
|
|
|
|
|
|
|
|
|
|||
|
Measuring range |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Gauge pressure |
mbar |
-600 ... |
0 |
-600 ... |
+600 |
-400 ... 0 |
-400 ... +400 |
-250 ... 0 |
|||||
|
|
|
-250 ... |
+250 |
-100 ... |
+100 |
-20 |
... +60 |
-20 |
... +40 |
-20 ... |
+25 |
||
|
|
|
0 ... |
25 |
|
0 ... |
40 |
|
0 ... |
60 |
0 ... |
100 |
0 ... |
160 |
|
|
|
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
|
|
|
|
||
|
|
bar |
-1 ... |
0 |
|
-1 ... |
1.5 |
-1 ... |
3 |
-1 ... |
5 |
-1 ... |
9 |
|
|
|
|
-1 ... |
15 |
|
-1 ... |
24 |
|
-1 ... |
39 |
0 ... |
1 |
0 ... |
1.6 |
|
|
|
0 ... |
2.5 |
|
0 ... |
4 |
|
0 ... |
6 |
0 ... |
10 |
0 ... |
16 |
|
|
|
0 ... |
25 |
|
0 ... |
40 |
|
0 ... |
60 |
0 ... |
70 |
0 ... |
100 |
|
|
|
0 ... |
160 |
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
0 ... |
1.000 |
||
|
|
psi |
-9 ... |
0 |
|
-9 ... |
+9 |
-4... |
0 |
-4 ... |
+4 |
-1,5... |
+1,5 |
|
|
|
|
-1,5 |
... 0 |
0 ... |
0,4 |
|
0 ... |
0,6 |
0 ... |
0,9 |
0 ... |
1,5 |
|
|
|
|
0 ... |
2,5 |
|
0 ... |
4 |
|
0 ... |
6 |
0 ... |
10 |
0 ... |
14,5 |
|
|
|
0 ... |
25 |
|
0 ... |
40 |
|
0 ... |
60 |
0 ... |
90 |
0 ... |
145 |
|
|
|
0 ... |
250 |
0 ... |
360 |
0 ... |
580 |
0 ... |
870 |
0 ... |
1,450 |
||
|
|
|
0 ... |
2,320 |
0 ... |
3,630 |
0 ... |
5,800 |
0 ... |
8,700 |
0 ... |
14,500 |
||
|
Absolute pressure |
mbar abs. |
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
|
|
|
|
||
|
|
bar abs. |
0 ... |
1 |
|
0 ... |
1.6 |
|
0 ... |
2.5 |
0 ... |
4 |
0 ... |
6 |
|
|
|
0 ... |
10 |
|
0 ... |
16 |
|
0 ... |
25 |
0,8 ... |
1,2 |
|
|
|
|
psi abs. |
0 ... |
4 |
|
0 ... |
9 |
|
0... |
14,5 |
0 ... |
25 |
0 ... |
60 |
|
|
|
0 ... |
90 |
|
0 ... |
145 |
0 ... |
250 |
|
|
|
|
|
|
Overpressure limit |
3 times; ? 25 bar |
... ? 600 bar |
|
|
3 times; ? 360 psi |
... ? 8,700 psi |
|
|
|||||
|
|
2 times; > 25 bar |
|
|
2 times; > 360 psi |
|
|
|||||||
|
|
1.5 times; > 600 bar |
|
|
|
|
1.5 times; > 8,700 psi |
|
|
|
||||
|
Resolution |
dependent on pressure range (max. 4 1/2-digit) |
|
|
|
|
|
|||||||
|
Accuracy of the measuring chain 1) |
0.2 % FS (resolution 4-digit); {optional: 0.1 % FS (resolution: 4 1/2-digit)} 2) |
|
|
||||||||||
|
Types of pressure |
Gauge pressure, {absolute pressure from 0 ... |
25 bar abs. (0 ... 360 psi abs.) and vacuum |
|
||||||||||
|
|
measuring ranges from -1 ... |
+24 bar (-14.5 ... |
550 psi)} |
|
|
|
|
||||||
|
|
Differential pressure measurement only with CPH62I0-S2, and two model CPT62I0 reference |
||||||||||||
|
|
pressure sensors connected |
|
|
|
|
|
|
|
|
|
|||
|
Sensor compatibility |
Compatible with model CPT62I0 reference pressure sensors |
|
|
|
|
||||||||