PASCAL 100 -- Hand-Held Multifunction Calibrator
Category: PRESSURE, CALIBRATORS, ELECTRICAL
Model: Portable Calibrators, Portable Calibrator, ELECTRICAL
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
PASCAL 100 -- Hand-Held Multifunction Calibrator
Category: PRESSURE, CALIBRATORS, ELECTRICAL
Model: Portable Calibrators, Portable Calibrator, ELECTRICAL
Avaibility: AVAILABLE
Call For Price
General
Due to its versatility the hand-held multifunction calibrator Pascal series is ideally suited for on-field testing and calibration of industrial measuring instruments. The typical application is the calibration of pressure transmitters, temperature transmitters, pressure gauges, temperature probes and other measuring instruments. The calibration data are stored in the instrument’s memory. The communication with a PC is used to remotely control the unit and to download the calibration reports.
The Pascal 100 is the most advanced portable multifunction calibrator for the measurement and simulation of the following parameters: relative and absolute pressure, electrical signals (mA, mV, V, ?), temperature (TC, RTD), frequency and pulse. In addition, there is the possibility to include an optional HART® module which allows communication with HART® instruments.
Features
The calibrator Pascal 100 has a new large touchscreen display with a new intuitive user-friendly interface, that allows an easy and fast configuration of the calibrator. The availability of ATEX approval II 2G Ex ib IIC T4 Gb - Tamb: -10 ... +50 °C expands the possible applications of this calibrator into hazardous areas (only for Pascal 100/IS). Even in the ATEX version the DC 24 V voltage supply for external transmitters is available. The calibrator has four measurement channels and is thus capable to carry out up to four simultaneous measures. For more flexibility on on-field calibrations, the Pascal 100 has an on-board memory for data storage that allows the evaluation of logged measuring values and calibration reports. In laboratory applications the real-time communication allows the remote control of the Pascal 100 from a PC.
The Pascal 100 can be modularly configured with up to two input and two output modules as well as one HART® module and one output module, which are galvanically isolated from each other. The measurement/simulation of the electrical signals or temperature as well as up to six pressure sensors (four internal and two external sensors) enables the operator to configure the calibrator according to his specific requirements. The environmental parameters module (option) is another plus of Pascal 100, it allows the monitoring of the barometric pressure, the ambient temperature and the relative humidity. The values will be stored in the calibration report.
Pressure
The Pascal 100 has an integrated pressure/vacuum generation by means of a built in hand pump from -0.9 ... +21 bar (-13 ... +300 psi). The presence of a fine precision regulator allows the operator to adjust small pressure increments. Many different pressure configurations are available, e.g.: ? in combination with internal pressure sensors that can be connected to the internal pump (up to 21 bar / 300 psi) ? in combination with external pressure sensors that can be connected directly to the external plugs. Low pressure internal sensors are protected against overpressure by means of protection valves. High flexibility in measurement is given by the availability of multiple pressure engineering units.
Applications
Special features
|
Base instrument |
|
|
Indication |
|
|
Display |
Touchscreen + 5 keys |
|
Dimension |
640 x 480 Dots |
|
Blacklight |
LED |
|
Electrical input and output |
|
|
Number & Type |
banana-plug inputs for electrical parameters, resistance thermometers and thermocouples |
|
Resistance thermometer (RTD) |
Pt100 (385, 3616, 3906, 3926, 3923), Pt200, Pt500, Pt1000 (385, 3916), Ni100, Ni120, Cu10, Cu100 |
|
Thermocouple |
Types J, K, T, F, R, S, B, U, L, N, E, C |
|
Voltage Signal |
input: DC ±100 mV, ±2 V, ±80 V |
|
Current Output |
input: DC ±100 mA |
|
Frequency Signal |
0 ... 50,000 Hz |
|
Pulses Signal |
1 ... 999,999 |
|
Resistance |
0 ... 10,000 ? |
|
Voltage Supply |
DC 24 V |
|
HART® communication |
|
|
HART Module |
based on HART® universal and common practice commands |
|
Resistance |
HART® resistance 250 ? (activatable) |
|
Loop Current |
max. DC 24 mA |
|
Voltage Supply |
DC 24 V |
|
Pressure connection |
1/8 BSP (female) |
|
Permissible media |
clean, dry, non-corrosive gases |
|
Temperature compensation |
-10 … +50 °C (14 ... 122 °F) |
|
Temperature coefficient |
0.001 % of reading/°C, outside of 19 ... 23 °C (66 ... 73 °F) |
|
Best Instrument |
|
|
Units |
bar, mbar, psi, psf, Pa, hPa, kPa, MPa, torr, atm, kg/cm?2;, kg/m?2;, mmHg (0 °C), cmHg (0 °C), mHg (0 °C), inHg (0 °C), mmH2O (4 °C), cmH2O (4 °C), mH2O (4 °C), inH2O (4 °C), ftH2O (4 °C) |
|
Voltage Supply |
|
|
Battery Type |
rechargeable battery NiMH |
|
Battery life (fully-charged) |
8 hours for typical usage |
|
Power Supply |
AC 100 ... 240 V, 50/60 Hz |
|
Permissible ambient conditions |
|
|
Operating Temperature |
-10 ... +50 °C (14 ... 122 °F) |
|
Storage Temperature |
-30 ... +80 °C (-22 ... +176 °F) |
|
Relative Humadity |
Operating humidity: 10 ... 90 % r. h. (non-condensing) Storage humidity: 0 ... 90 % r. h. (non-condensing) |
OTHER PRODUCT