CPC7000 -- Pneumatic High-Pressure Controller
Category: PRESSURE, CALIBRATORS
Model: Pressure Controller, Pressure Controllers
Avaibility: OUT OF STOCK
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
CPC7000 -- Pneumatic High-Pressure Controller
Category: PRESSURE, CALIBRATORS
Model: Pressure Controller, Pressure Controllers
Avaibility: OUT OF STOCK
Call For Price
Version
The CPC7000 pneumatic high-pressure controller always provides a suitable calibration solution on account of its accuracy class. Its outstanding control performance is particularly impressive thanks to special valve technology and the high-accuracy pressure sensor as a measuring unit. With this the controller is suitable as a factory or working standard for the testing or calibration of any type of pressure measuring instrument.
Design
The CPC7000 is available as a desktop instrument or as a 19" rack-mounting kit. The sensors can be changed via the front, without having to take out the complete controller, e.g. out of a calibration rig (plug-and-play).
Functionality
The touchscreen, through its intuitive user interface, delivers ease of use. The large number of menu languages adds to its user friendliness. In addition to specifying a specific pressure set point, either by entering it via touchscreen or sending it via remote interface, the pressure can be changed in defined, programmable steps by using the STEP buttons. Moreover, the user can also easily create extensive test programs using the instrument menu. Depending on the application, the control rate can be set as a user-defined variable rate.
Software
The WIKA-CAL calibration software enables the convenient calibration of pressure measuring instruments and the gener-ation of test certificates. Additionally, the instrument can also be remotely controlled using the serial command formats, the Mensor standard, SCPI or further optional command sets are available.
Complete test and calibration systems
On request, complete mobile or stationary test systems can be manufactured. There is an IEEE-488.2, RS-232, USB and an Ethernet interface for communication with other instruments, and thus the instrument can be integrated into existing systems.
|
Pressure range |
CPR8000 |
CPR8050 |
|
Accuracy 1) |
Standard: 0.01 % Full span 2) |
0.01 % Full span 2) |
|
|
Option: 0.01 % IS-50 3) |
|
|
Gauge pressure |
100 ... 400 bar |
400 ... 700 bar |
|
|
(1,500 ... 6,000 psi) |
(6,000 ... 10,000 psi) |
|
Absolute pressure |
101 ... 401 bar |
401 ... 701 bar |
|
|
(1,515 ... 6,015 psi) |
(6,015 ... 10,015 psi) |
|
Calibration interval |
365 days |
365 days |
|
Optional barometric reference |
The barometric reference can be used to switch pressure types 4), absolute <=> gauge. With gauge |
|
|
Function |
||
|
|
pressure sensors, the measuring range of the sensors must begin with -1 bar (-15 psi) in order to carry |
|
|
|
out an absolute pressure emulation. |
|
|
Measuring range |
552 ... 1,172 mbar abs. (8 ... 17 psi abs.) |
|
|
Accuracy 1) |
0.01 % of reading |
|
|
Pressure units |
38 and two freely programmable |
|
|
Instrument version |
Standard: Desktop case |
|
|
Option: 19" rack-mounting kit |
|
Dimensions |
see technical drawings |
|
Weight |
approx. 40 kg (88.2 lbs) |
|
Warm-up time |
approx. 15 min |
|
Display |
|
|
Screen |
8.9" LC colour display with resistive touchscreen |
|
Resolution |
4 ... 6 digits depending on range and units |
|
Connections |
|
|
Pressure connection |
M16 x 1.5 female with sealing cone |
|
|
Optional barometer: M12 female thread |
|
Filter elements |
All pressure connections of the instrument feature a 20-µm filter. |
|
Permissible pressure media |
Minimum nitrogen 2.8 or better |
|
Overpressure protection |
Burst disc up to 1,000 bar (14,500 psi) |
|
Permissible pressure |
|
|
Supply port |
107 … 110 % FS at least 30 … 50 bar (435 ... 725 psi) over nominal pressure |
|
Measure/Control port |
max. 105 % FS |
|
Voltage supply |
|
|
Power supply |
AC 100 ... 240 V, 50 Hz / 60 Hz |
|
Power consumption |
max. 120 VA |
|
Permissible ambient conditions |
|
|
Storage temperature |
0 ... 70 °C (32 ... 158 °F) |
|
Humidity |
5 … 95 % r. h. (non-condensing) |
|
Compensated temperature range |
15 ... 45 °C (59 ... 113 °F) |
|
Mounting position |
horizontal |