Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

WIKA

CED 7000 -- High Precision Process Calibrator

Category: ELECTRICAL

Model: ELECTRICAL

Avaibility: AVAILABLE

Call For Price

General information

The model CED7000 process calibrator combines the capabilities of a signal, temperature and pressure calibrator in a single instrument. With the efficiency of a laboratory instrument, an additional isolated measuring channel and optional external pressure modules, the CED7000 is perfect for the widest range of calibration tasks.

Extensive application possibilities

The CED7000 has a wide range of application options. It can be used for calibration in industry (laboratory, production, workshops) and in laboratories and institutes.

Efficiency

The signal calibration capability of the CED7000 includes current, voltage and resistance. In the thermocouple and resistance thermometer mode, the unit offers a selection between 13 different thermocouples and 9 different resistance thermometers.

For pressure measurement, an external pressure sensor is required. The best results are achieved by using the CPT6100 series. The accuracy and the resolution are dependent on the respective pressure sensor. The fully isolated measuring channel enables the calibration of transmitters. The CED7000 thus combines the two functions, measuring and simulation, in one instrument. The CED7000 is very easy to use. It supports direct entry using keyboard or cursor keys. The CED7000 can be controlled via PC using RS-232, IEEE-488 or optionally a USB connection.

Certified accuracy

Every process calibrator CED7000 is provided with a factory calibration certificate which certificates the accuracy of the instrument. On request, we can provide a DKD/DAkkS calibration certificate for this instrument.

Applications

  • Research and development laboratories
  • Calibration service companies and service industry
  • Industry (laboratory, workshop and production)
  • Quality assurance

Special features

  • Excellent accuracy of down to 0.0025 % of reading
  • Measuring and simulation of thermocouples (13), resistance thermometers (9), resistance, voltage, current and pressure
  • Entry of customer-specific resistance thermometer coefficients
  • Beryllium copper connections reduce thermoelectric voltages
  • Insulated mA/V measuring channel for complete transmitter calibration (measuring and simulation at the same time)

Base instrument

Input and output

Resistance thermometer (RTD)

Pt100 (385, 3926, 3916), Pt200, Pt500, Pt1000, Ni120, Cu10, YSI 400

Thermocouples

Types B, C, E, J, K, L, N, R, S, T, U, XK, BP

Voltage signal

DC 0 ... 100 V

Current signal

DC 0 ... 100 mA (output)
DC 0 ... 50 mA (input)

Transmitter supply

Voltage supply

DC 24 V ±10 V

Loop current

max. DC 24 mA

Resistance

HART® resistor: 250 ? ±3 ? (activatable)

Special Feature

Setting Time

less than 5 seconds

Warm-up time

30 minutes

Voltage Supply

Power Supply

AC 100 ... 240 V, 47 ... 63 Hz

Power Consumsion

max. 15 VA

Permissible ambient conditions

Operating temperature

0 ... 50 °C

Storage temperature

-20 ... +70 °C

Calibration temperature (Tcal)

18 ... 28 °C

Temperature coefficient

10 % of the accuracy specification per °C outside the calibration temperature

Relative humidity

Operation

< 80> < 70> < 40>

Storage

0 ... 95 % r. h. (non-condensing)

Communication

Interface

RS-232, IEEE-488 (GPIB)

Case

Dimension

48.3 x 17.7 x 27.9 cm (19.0 x 7.0 x 11.0 inch)

Weight

4 kg (8.82 lb)

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.