CPT2500 -- USB Pressure Sensor With USB Adapter
Category: PRESSURE
Model: Pressure Sensor
Avaibility: OUT OF STOCK
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
CPT2500 -- USB Pressure Sensor With USB Adapter
Category: PRESSURE
Model: Pressure Sensor
Avaibility: OUT OF STOCK
Call For Price
Extensive application possibilities
The model CPT2500 USB pressure sensor can be connected to any PC with a USB interface, via the model CPA2500 USB adapter.
For the USB adapter, there are stainless steel pressure sensors with measuring ranges up to 1,000 bar (14,500 psi) available. The USB adapter automatically recognises the measuring range of the connected pressure sensor and guarantees a high-accuracy pressure measurement.
Functionality
The measuring interval for pressure recording can be set in the range from 1 ms ... 10 s. With a recording interval of more than 5 ms the following data is recorded in addition to the current measured value:
Thus pressure spikes within the overall recording interval can be very easily identified. It is also possible to set start and stop conditions for the recording. In this way it is possible to detect pressure spikes with a resolution of up to 1 ms. The CPT2500 is thus very well suited to all applications where, over a limited time span, pressure profiles must be recorded and analysed with high resolution.
Software
The USBsoft2500 and USB-ScanSoft software are delivered as standard with the USB adapter. With it, all settings for recording the pressure profiles can be made. The recorded measured values can be graphically displayed and evaluated.
Apart from the USBsoft2500 and USB-ScanSoft software, the WIKA-Cal calibration software is available for calibration tasks. Using this software, the data is automatically transferred into a printable calibration certificate. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. A USB interface is available for the data transfer.
Complete service case
For easy transport and safe storage, the USB adapter is delivered in a compact transport case, which can also hold one or more pressure sensors.
Certified accuracy
For each reference pressure sensor, the accuracy for the complete measuring chain is certified by a factory calibration certificate which accompanies the instrument. On request, a DKD/DAkkS calibration certificate will be provided for this instrument.
|
Gauge pressure |
mbar |
-600 ... |
0 |
-600 ... |
+600 |
-400 ... |
0 |
-400 ... |
+400 |
-250 ... |
0 |
|
||||||
|
|
|
-250 ... |
+250 |
-100 ... |
+100 |
-20 |
... +60 1) |
-20 |
... +40 1) |
-20 ... |
+25 1) |
|
||||||
|
|
|
0 ... |
25 1) |
0 ... |
40 1) |
0 ... |
60 1) |
0 ... |
100 |
0 ... |
160 |
|
||||||
|
|
|
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
|
|
|
|
|
|
|
||||
|
|
bar |
-1 ... |
0 |
|
-1 ... |
1.5 |
-1 ... |
3 |
|
-1 ... |
5 |
|
-1 ... |
9 |
|
|
||
|
|
|
-1 ... |
15 |
|
-1 ... |
24 |
|
-1 ... |
39 |
|
0 ... |
1 |
|
0 ... |
1.6 |
|
|
|
|
|
|
0 ... |
2.5 |
|
0 ... |
4 |
|
0 ... |
6 |
|
0 ... |
10 |
|
0 ... |
16 |
|
|
|
|
|
|
0 ... |
25 |
|
0 ... |
40 |
|
0 ... |
60 |
|
0 ... |
70 |
|
0 ... |
100 |
|
||
|
|
|
0 ... |
160 |
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
0 ... |
1,000 |
|
||||||
|
|
psi |
-9 ... |
0 |
|
-9 ... |
+9 |
-4... |
0 |
|
-4 ... |
+4 |
-1.5... |
0 |
|
||||
|
|
|
-1.5 |
... +1.5 |
0 ... |
0.4 |
|
0 ... |
0.6 |
|
0 ... |
0.9 |
|
0 ... |
1.5 |
|
|
||
|
|
|
0 ... |
2.5 |
|
0 ... |
4 |
|
0 ... |
6 |
|
0 ... |
10 |
|
-14.5 ... |
0 |
|
||
|
|
|
-14.5 ... |
23 |
-14.5 ... |
44 |
-14.5 ... |
70 |
-14.5 ... |
130 |
-14.5 ... |
220 |
|
||||||
|
|
|
-14.5 ... |
350 |
-14.5 ... |
560 |
0 ... |
14.5 |
0 ... |
25 |
|
0 ... |
40 |
|
|
||||
|
|
|
0 ... |
60 |
|
0 ... |
90 |
|
0 ... |
145 |
0 ... |
250 |
0 ... |
360 |
|
||||
|
|
|
0 ... |
580 |
0 ... |
870 |
0 ... |
1,000 |
0 ... |
1,450 |
0 ... |
2,320 |
|
||||||
|
|
|
0 ... |
3,630 |
0 ... |
5,800 |
0 ... |
8,700 |
0 ... |
14,500 |
|
|
|
|
|||||
|
Absolute pressure |
mbar abs. |
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
|
|
|
|
|
|
|
||||
|
|
bar abs. |
0 ... |
1 |
|
0 ... |
1.6 |
|
0 ... |
2.5 |
|
0 ... |
4 |
|
0 ... |
6 |
|
|
|
|
|
|
0 ... |
10 |
|
0 ... |
16 |
|
0 ... |
25 |
|
0.8 ... |
1.2 |
|
|
|
|
||
|
|
psi abs. |
0 ... |
4 |
|
0 ... |
6 |
|
0 ... |
10 |
|
0 ... |
14.5 |
0 ... |
25 |
|
|
||
|
|
|
0 ... |
60 |
|
0 ... |
60 |
|
0 ... |
90 |
|
0 ... |
145 |
0 ... |
250 |
|
|||
|
|
|
0 ... |
360 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Overpressure limit |
3 times; ? 25 bar |
... ? 600 bar |
|
|
|
3 times; ? 360 psi |
... ? 8,700 psi |
|
|
|
|
|||||||
|
|
2 times; > 25 bar |
|
|
|
2 times; > 360 psi |
|
|
|
|
|||||||||
|
|
1.5 times; > 600 bar |
|
|
|
|
1.5 times; > 8,700 psi |
|
|
|
|
|
|
||||||
|
Resolution |
dependent on pressure range (max. 4 1/2-digit) |
|
|
|
|
|
|
|
|
|
||||||||
|
Accuracy of the measuring chain 2) |
0.2 % FS (resolution 4-digit); {optional: 0.1 % FS (resolution: 4 1/2-digit)} 3) |
|
|
|
|
|||||||||||||
|
Pressure types |
Gauge pressure, {absolute pressure from 0 ... |
25 bar abs. (0 ... 360 psi abs.) and vacuum from |
|
|||||||||||||||
|
|
-1 ... +39 bar (-14.5 ... |
560 psi)}, |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|||||||||||
|
Process connection 4) |
G ½ B; {flush (G 1 for 0.1 ... 1.6 bar (1.5 ... 23 psi)) or various connection adapters on request) |
|
Pressure units |
mbar, bar, Pa, kPa, MPa, mmHg, psi, inHg (0 °C), inHg (60 °F), mWs; (depending on the measuring |
|
|
range, freely selectable) |
|
Material |
Stainless steel or Elgiloy®, (> 25 bar (360 psi) additionally with NBR seal) 5) |
|
Wetted parts |
|
|
|
Flush diaphragm version: Stainless steel {Hastelloy C4}; O-ring: NBR {FKM/FPM or EPDM} |
|
Internal transmission medium |
Synthetic oil (only for measuring ranges to 16 bar (250 psi) or flush diaphragm) |
|
|
{Halocarbon oil for oxygen applications}; {Listed by FDA for food industry} |
|
Sensor data |
|
|
Accuracy 2) |
? 0.2 % of span (at reference conditions) 3) |
|
Compensated range |
0 ... 80 °C (32 ... 176 °F) |
|
Mean temperature coefficient |
? 0.2 % of span/10 K (outside the reference conditions) |
|
Measuring rate |
1,000 measurements/s |
|
Permissible ambient conditions |
|
|
Medium temperature 4) |
-25 ... +100 °C (-13 ... +212 °F) 6) |
|
Operating temperature |
-20 ... +80 °C (-4 ... +176 °F) |
|
Storage temperature |
-40 ... +100 °C (-40 ... +212 °F) 6) |
|
Relative humidity |
0 ... 95 % r. h. (non-condensing) |
|
Case |
|
|
Material |
Stainless steel |
|
Ingress protection |
IP67 |
|
Dimensions |
See technical drawing |
|
Weight |
approx. 220 g (0.49 lbs) |