Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

TESTO

Testo Saveris 2

Category: DATA LOGGER, TEMPERATURE, HUMIDITY

Model: Humidity, Temperature, Temperature Data Logger, Humidity Data Logger

Avaibility: AVAILABLE

Call For Price

  • Data transfer by wireless LAN
  • All measurement data always available, anywhere, on any instrument
  • Alarms when limit values are violated
  • With testo Saveris 2 App for easier configuration, push alarms and WiFi range analysis
  • Cost-free online data store (Testo Cloud)

The testo Saveris 2 WiFi data logger system is the modern solution for monitoring temperature and humidity values as well as CO2 concentration in storerooms and work rooms. Installing the system is child's play, and can be carried out either via a browser, or with the testo Saveris 2 App. The WiFi data loggers reliably record  temperature,  humidity and CO? concentration at adjustable intervals and transmit the measurement values directly by wireless LAN to the Testo Cloud.

The readings stored can be analyzed at any time, anywhere, using an internet-enabled smartphone, tablet or PC.Limit value violations are immediately reported by e-mail, optionally by SMS or via the testo Saveris 2 App as a push notification. This allows critical processes to be kept always under control, even if you are not on site. The long battery life additionally ensures that the testo Saveris 2 system needs to be serviced only rarely.

testo Saveris 2 Cloud

Our packages

The Testo Cloud is the core operating element for setting up your testo Saveris 2 system. Here you can configure your WiFi data loggers, set limit value alarms and analyze your measurement data. You must first register at www.saveris.net to have access to the Testo Cloud. Depending on the desired range of functions, you have a choice between the free Basic and    more extensive Advanced functionality for use of  the Testo Cloud. In  both packages, you have access to  an  API interface,  in order to export measurement data to your systems.

 

Basic

Advanced

Measuring cycle

15 min to 24 h

1 min to 24 h

Communication cycle

15 min to 24 h

1 min to 24 h

Data storage

Max. 3 months

Max. 2 years

Reports

Manual (.pdf/.csv)

Manual (.pdf/.csv) Automatic (.pdf/.csv)

Data analysis

For one measurement site each (external probes count as measurement sites)

For up to 10 measurement channels simultaneously

Number of users per account

1

10

Number of WiFi data loggers per account

Unlimited

Unlimited

 

Alarm options

 

Upper/lower alarm limits

  • Upper/lower alarm limits
    • Alarm delay
  • Time control of alarms

 

System notifications

  • Notification of low battery
    • Radio link interrupted
  • Power supply interrupted
  • Notification of low battery
    • Radio link interrupted
  • Power supply interrupted

E-mail alarm

Yes

Yes

SMS alarm

No

  • Including 25 SMS per logger and year
  • Option of purchasing additional SMS packages
   

12-month licence Order no. 0526 0735

24-month licence Order no. 0526 0732

36-month licence Order no. 0526 0733

Technical data

 

testo Saveris 2- T1

testo Saveris 2- T2

testo Saveris 2- T3

testo Saveris 2- H1

testo Saveris 2- H2

testo 160 IAQ

Temperature measurement

Sensor type

NTC internal

NTC

TC Type K

TC Type J

TC type T

NTC internal

NTC

 

Measuring range

-30 to

+50 °C

-50 to

+150 °C

-195 to

+1350 °C

-100 to

+750 °C

-200 to

+400 °C

-30 to

+50 °C

Measuring range and accuracy correspond to probe

0 to +50 °C

 

Accuracy ±1 digit

 

±0.5 °C

 

±0.3 °C

 

±(0.5 + 0.5 % of m.v.) °C

 

±0.5 °C

 

±0.5 °C

Resolution

0.1 °C

0.1 °C

Humidity measurement

Measuring range

0 to 100 %RH

 

 

Measuring range and accuracy correspond to probe

0 to 100 %RH

 

 

 

Accuracy

 

 

 

 

 

 

±2 %RH

±2 %RH at +25 °C and

20 to 80 %RH

±3 %RH at +25  °C

and  <20>

>80 %RH

±1%  RH hysteresis

±1% RH / year drift

Resolution

0.1 %RH

CO2 measurement

Measuring range

0 to 5 000 ppm

 

 

Accuracy

 

 

±(50 ppm + 3 % of  m.v.) at +25 °C   Without external power supply:

±(100 ppm + 3 % of

m.v.) at +25 °C

Resolution

1 ppm

Pressure measurement

Measuring range

600 to 1100 mbar

Accuracy

±3 mbar at +22 °C

Resolution

1 mbar

Temperature/humidity measurement via external probes

 

External probe connection

 

External temperature probes

 

External temperature probes

 

External humidity/ temperature probe

 

General technical data

Operating temperature

-30 to +50 °C

0 to +50 °C

Storage temperature (without batteries)

-40 to +70 °C

-20 to +50 °C

Protection class

IP65

IP65

IP54

IP30

IP54

IP20

Measuring cycle

Depends on the Cloud licence / Basic: 15 min to 24 h / Advanced: 1 min to 24 h testo 160 IAQ – Advanced in battery operation: 5 mins to 24 h

Communication cycle

Depends on the Cloud licence / Basic: 15 min to 24 h / Advanced: 1 min to 24 h

Memory

10000 readings/channel

32,000 readings (sum of all channels)

Standards / permits

EN 12830

EN 12830

 

Battery life

12 months (typical value, depending on the wireless LAN infrastructure) at +25 °C,

15 mins measurement rate and standard communication rate at -30 °C, 15 mins measurement rate and standard communication rate with Energizer batteries 0515 0572

 

12 months

 

 

Voltage supply

 

4 x AA AlMn Mignon batteries; mains unit optional;

for temperatures under -10 °C please use Energizer batteries 0515 0572

4 x AA alkali manganese batteries

1.5 V, alternatively mains unit via USB

connection

Dimensions

95 x 75 x 30.5 mm

115 x 82 x

31 mm

95 x 75 x 30.5

mm

117 x 82 x 32 mm

Weight

(including batteries)

240 g

250 g

240 g

269 g

Door contact

No

Optional

No

Communication

 

WiFi (wireless LAN)

Signal transmission: wireless; frequency band: 2.4 GHz; supported wireless LAN standards: IEEE 802.11 b/g/n and IEEE 802.1X Possible encryption methods: without encryption, WEP, WPA, WPA2, WPA2 Enterprise

The data loggers communicate via the standard protocol MQTT and are SNTP time synchronization-capable.

Ordering data for accessories

Accessories Order no.
Door contact for testo Saveris 2-T2 WiFi data logger 0572 2152
Mains unit for testo Saveris 2 WiFi data loggers 0572 2020
Battery for WiFi probes (4 x AA alkali manganese Mignon batteries)) 0515 0414
Batteries for operating WiFi data loggers testo Saveris 2 below -10 °C (4 x Energizer L91 Photo-Lithium) 0515 0572
Magnetic adapter for testo Saveris 2 wall bracket, for attachment to magnetic surfaces 0554 2001
Wall bracket for testo 160 IAQ 0554 2015
Deco-cover for testo 160 IAQ 0554 2012
ISO temperature calibration certificate, temperature probe; calibration points -18 °C, 0 °C, +40  °C; per channel/instrument 0520 0153
DAkkS temperature calibration certificate; temperature probe; calibration points -18 °C, 0 °C, +40  °C; per channel/instrument 0520 0262
ISO humidity calibration certificate; calibration points 11.3 %RH and 75.3 %RH at +25 °C/ +77 °F;  per channel/instrument 0520 0076
DAkks humidity calibration certificate; humidity probe; calibration points 11.3 %RH and 75.3 %RH at  +25°C; per channel/instrument 0520 0246