Measures all IAQ-related parameters: Flow, temperature, humidity, pressure, illuminance, radiant heat, turbulence, CO? and CO
High-precision, location-independent and integrated differential pressure sensor
High-quality digital probes and an intelligent calibration concept
Document measuring values directly on the customer's site and send them by e-mail, or further analyze them using the testo DataControl PC software
Smart and intuitive measurement programs:-
HVAC grid measurement in accordance with EN ISO 12599 and ASHRAE 111
testo 400 is the universal measuring instrument for all IAQ professionals, enabling them to measure, document and analyze all IAQ parameters with just one instrument. Your benefits:
As consultants, experts, technical service providers or ser- vice technicians in the air conditioning and ventilation sec- tor, the testo 400 therefore supports you in the truly smart performance of your measuring tasks. Relevant quality parameters in industrial production and manufacturing pro- cesses can also be reliably and accurately checked using the testo 400.
Technical data
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
*TUC connection (Testo Universal Connector): For the connection of fixed cable digital probes and NTC probes.
Accessories
|
Calibration certificates |
Order no. |
|
ISO flow calibration certificate; hot wire/vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s |
0520 0004 |
|
ISO flow calibration certificate; hot wire/vane anemometer, Pitot tube; calibration points 0.3; 0.5; 0.8; 1.5 m/s |
0520 0024 |
|
ISO flow calibration certificate; hot wire/vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s |
0520 0034 |
|
ISO flow calibration certificate; hot wire/vane anemometer, Pitot tube; selective calibration points in the 0.5 to 27 m/s range |
0520 0104 |
|
DAkkS flow calibration certificate; hot wire/vane anemometer, Pitot tube; selective calibration points in the 0.1 to 27 m/s range |
0520 0214 |
|
DAkkS flow calibration certificate; hot wire/vane anemometer, Pitot tube; calibration points 0.5; 1; 2; 5; 10 m/s |
0520 0244 |
|
ISO pressure calibration certificate; 5 calibration points; accuracy > 0.6% of f.v. |
0520 0005 |
|
ISO pressure calibration certificate; 5 calibration points; accuracy 0.1 to 0.6% of f.v. |
0520 0025 |
|
DAkkS pressure calibration certificate; 5 calibration points; accuracy > 0.6% of f.v. |
0520 0225 |
|
ISO humidity calibration certificate, electronic hygrometer; calibration points 11.3 %RH and 75.3 %RH at +25 °C |
0520 0006 |
|
ISO humidity calibration certificate; electronic hygrometer; calibration points 11.3; 50; 75.3 %RH at +25 °C |
0520 0166 |
|
DAkkS humidity calibration certificate; electronic hygrometer; calibration points 11.3 %RH and 75.3 %RH at +25 °C |
0520 0206 |
|
DAkkS humidity calibration certificate; electronic hygrometer; selective calibration points 5 to 95 %RH at -18 to +70 °C |
0520 0216 |
|
ISO temperature calibration certificate, for air/immersion probe, calibration points -18°C; 0 °C; +60 °C |
0520 0001 |
|
ISO temperature calibration certificate for air/immersion probe, selective calibration points in the -196 to +1200 °C range |
0520 0101 |
|
DAkkS temperature calibration certificate for air/immersion probe, selective calibration points in the -196 to +1000 °C range |
0520 0201 |
|
DAkkS temperature calibration certificate; measuring instruments with air/immersion probe; calibration points -20 °C; 0 °C; +60 °C |
0520 0211 |
|
ISO luminous intensity calibration certificate; calibration points 0; 500; 1000; 2000; 4000 lux |
0520 0010 |
|
ISO luminous intensity calibration certificate; selective calibration points in the 0; 50 to 10,000 lux range |
0520 0123 |
|
ISO CO? calibration certificate; CO? probes; calibration points 0; 1000; 5000 ppm |
0520 0033 |