Talk with one of our sales

Monday to Friday 8AM - 5PM WIB

021- 72791867

Product

Home / Product

DELTA T

GP1 -- Soil Moisture, Temperature, & Rainfall Data Logger

Category: DATA LOGGER

Model: Other

Avaibility: AVAILABLE

Call For Price

With its simple software, long battery life and large memory, the GP1 is very easy to set up and maintain. It is well suited to outdoor logging applications ? the waterproof (IP67) case does not require a secondary enclosure. The GP1's small size allows it to be installed in confined spaces, or to be hidden away if security is an issue.   The internal alkaline battery lasts for >1 year   when taking hourly readings from 2   moisture sensors, 2 temperature   sensors and a rain gauge.

- High accuracy 7 channel data logger

- 600,000 readings

- Compatible with DeltaLINK?Cloud online data viewing and sharing platform

- Smart relay control

Applications

?      Monitoring soil moisture

?      Environmental data logging

?      Climate research and meteorolog

Specifications

 

Typical at +20 °C

 

Max ?20 °C to +60 °C

 

Notes

 

 

 

Differential Voltage Channels

Voltage accuracy

± (0.3 mV + 0.01% reading)

± (1.6 mV + 0.05% reading)

over full ?0.2 V to +2.7 V voltage range

Soil moisture accuracy

±0.06%? (±0.0006 m3.m?3)

±0.3%vol? (±0.003 m3.m?3)

with ML3 or SM150T (0 to 60% ?) [1]

Resolution / input noise

±0.1 mV

effective resolution of readings (typical)

Input voltage range

?0.2 V to +2.7 V

 

Input voltage limits

?2.8 V to +3.6 V [2]

each input signal relative to logger GND

 

Temperature Channels

Temperature accuracy

±0.07 °C

±0.1 °C (with GP1 below 30 °C if reading ?20 to 0 °C)

using 10K thermistor ?20 to +60 °C [1]

Resistance accuracy

±0.2% of 2 to 100K? reading

(±0.3% max)

±0.5% of 2 to 20K? reading

 

 

Event Counters

Event counter (Event6)

< 50>

 

logic low input < 1> 1.9 V,

maximum ±14 V on Event inputs 5 and 6

High speed counter (Event5)

< 33k>

 

 

Power

Internal battery life

1 year typical (alkaline)

9V PP3 battery [3]

External power

11 to 24 V DC

power via external M8 connector

Switched sensor power

up to 120 mA: > 10 V if external power > 13.8 V

switched battery or external power

+5 V reference

5 V ±0.6%

5 V ±1.6%

switched voltage reference, up to 50 mA

Relay Channel

1 x relay

SPST, < 30>

separate ON / OFF conditions adjustable ON duty cycle

 

 

Data Recording

Logging frequency

1 second to 24 hour

user configurable logging frequency

Sensor warm?up

multiples of 1 second

user configurable sensor warm?up times

Internal flash memory

> 600k readings, typical

non?volatile flash memory

Communications

RS232 (115 kbaud) / USB [4]

comms via external M8 connector or USB [4]

 

 

Physical

Environmental

water resistant to IP67

4 cable glands, connector & case

Size and weight

140 x 105 x 45 mm, 280 g

including battery

Temperature

?20 to +60 °C

 