Specifications: Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp

Specifications: Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp

FunctionRangeResolutionAccuracy
AC volts[1]6.000 V0.001 V1.0 % + 3 (45 Hz to 500 Hz)
60.00 V0.01 V
600.0 V0.1 V2.0 % + 3 (500 Hz to 1 kHz)
1000 V1 V
DC volts6.000 V0.001 V0.09 % + 3
60.00 V0.01 V
600.0 V0.1 V
1500 V1 V0.15 % + 2
AC mV[1]600.0 mV0.1 mV1.0% + 3 (45 Hz ~ 500 Hz) 2.0% + 3 (500 Hz ~ 1000 Hz)
DC mV600.0 mV0.1 mV0.09 % + 2
Continuity600 ?1 ?
Resistance600.0 ?0.1 ?0.5 % + 4
6.000 k?0.001 k?
60.00 k?0.01 k?
600.0 k?0.1 k?
6.000 M?0.001 M?
50.00 M?0.01 M?1.5 % + 4
Capacitance1000 nF1 nF1.2 % + 2
10.00 ?F0.01 ?F
100.0 ?F0.1 ?F
9999 ?F1 ?F10 % typical
Frequency99.99 Hz0.01 Hz0.1 % + 2
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
AC VA (45~500Hz)[1]360.0 VA0.1 VA2 % + 1.0 VA
3.600 kVA0.001 kVA2 % + 0.01 kVA
36.00 kVA0.01 kVA2 % + 0.1 kVA
60.00 kVA0.01 kVA2 % + 0.15 kVA
DC VA[1]360.0 VA0.1 VA2 % + 1.0 VA
3.600 kVA0.001 kVA2 % + 0.01 kVA
36.00 kVA0.01 kVA2 % + 0.1 kVA
90.00 kVA0.01 kVA2 % + 0.25 kVA
Min-max avgFor DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.
For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration.

[1] <1% range, unspecified

Environmental specifications
Operating temperature-10 °C to 60 °C
Storage temperature-30 °C to +70 °C
Humidity (without condensation)0 % to 90 %, 10 °C to 30 °C
0 % to 75 %, 30 °C to 40 °C
0 % to 45 %, 40 °C to 60 °C
Warranty and Protection
Electromagnetic compatibilityIEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A
Overvoltage categoryCAT III 1500 V, CAT IV 1000 V
Agency approvalsETL (AMER and EMEA), CSA (APAC), CE, UK CA
Drop test2 meter (6.5 ft) drop test
Ingress protectionIP52
WarrantyLimited lifetime
Mechanical and general specifications
Counts6000
Size22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in)
Weight0.7 kg (1.5 lb)
Battery life> 150 hours typical, without backlight (Alkaline, 3 AA)
> 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)

a283 FC Wireless Current Clamp

FunctionRangeResolutionAccuracy
AC current (True-RMS)[2]60 A0.01 A1.5% + 0.15 A, 45?500Hz
DC current[2]60 A0.01 A1.5% + 0.15 A
General specifications – Fluke a283 FC Wireless Current Clamp
Operating temperature-10 °C to 60 °C
Storage temperature-30 °C to +70 °C
Humidity (without condensation)0 % to 90 %, 5 °C to 30 °C
0 % to 75 %, 30 °C to 40 °C
0 % to 45 %, 40 °C to 60 °C
Warranty and Protection
Electromagnetic compatibilityIEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A
Overvoltage categoryCAT III 1500 V, CAT IV 1000 V
Agency approvalsETL (AMER and EMEA), CSA (APAC), CE, UK CA
Drop test2 meter (6.5 ft) drop test
Ingress protectionIP52
Warranty1-year
Mechanical and general specifications
Size226.0 mm x 91.0 mm x 42.0 mm (8.9 in x 3.6 in x 1.7 in)
Jaw opening34 mm (1.34 in)
Weight0.375 kg (13.2 oz)
Battery life> 80 hours typical (Alkaline, 2 AAA)
Features
LED indicatorIndicates wireless connection and data transmission status
Battery indicatorIndicates battery status
Power KeyPower On/Off
Zero KeyA DC zeroing function

[2] <1% range, unspecified