Product Specifications
Product Specifications
| General specifications | |
| AC mains voltage | 100 V to 240 V ± 10 % |
| Standard frequency range | 47 Hz to 63 Hz |
| Power consumption | 300 VA |
| Required test fluid | Distilled water |
| Warm-up period | Twice the time since last warmed up, to a maximum of 30 minutes |
| Mains fuse rating | F 4A 250 V (fast blow) |
| Operating ambient relative humidity range, 18 °C to 28 °C | Up to 80 % RH |
| Storage temperature and relative humidity | -20 °C to 50 °C, 0 % to 95 % RH, non-condensing |
| Transducer power output | 12 V dc, 1 A maximum, fuse: F 1A 250 V (fast blow) |
| Computer interface | USB |
| Safety | IEC 61010-1, Installation Category II, Pollution degree 2, Indoor use only |
| Altitude | 2000 m |
| Electromagnetic compatibility (EMC) | |
| International | IEC 61326-1: Controlled electromagnetic environment CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. |
| Korea (KCC) | Class A Equipment (Industrial, broadcasting, and communication equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Weight | |
| Chassis only | 15 kg (33.06 lbs) |
| Dimensions | |
| Chassis | 237 mm × 432 mm × 521 mm (9.3 in × 17 in × 20.5 in) (height × width × depth) |
| Overall chamber dimensions | 200 mm (7.87 in) (depth) × 150 mm (5.90 in) (diameter) |
| Working volume dimensions | 109 mm (4.3 in) (depth) × 125 mm (4.92 in) (diameter) |
| Temperature resolution | |
| Display | 0.1 °C |
| USB data | 0.1 °C |
| Humidity resolution | |
| Display | 0.1 % RH |
| USB data | 0.1 % RH |
| Dew point | |
| Resolution | 0.1 °C (for indication only) |