Fluke 116 HVAC Multimeter
Category: TEMPERATURE, ELECTRICAL
Model: Handheld Temperature Calibrator and Indicator, Digital Multimeter
Avaibility: AVAILABLE
Call For Price
Talk with one of our sales
Monday to Friday 8AM - 5PM WIB
021- 72791867
Fluke 116 HVAC Multimeter
Category: TEMPERATURE, ELECTRICAL
Model: Handheld Temperature Calibrator and Indicator, Digital Multimeter
Avaibility: AVAILABLE
Call For Price
Specifications: Fluke 116 Digital HVAC Multimeter
Specifications: Fluke 116 Digital HVAC Multimeter
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to + 50°C | |
| Storage temperature | -40°C to + 60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 ? / 1 ? |
| Accuracy | Beeper on < 20 ?, off > 250 ? detects opens or shorts of 500 ?s or longer. | |
| Ohms | Range/resolution | 600.0 ? / 0.1 ? 6.000 k? / 0.001 k? 60.00 k? / 0.01 k? 600.0 k? / 0.1 k? 6.000 M? / 0.001 M? |
| Accuracy | 0.9% + 1 | |
| Range/Resolution | 40.00 M? / 0.01 M? | |
| Accuracy | 5% + 2 | |
| Diode Test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 ?F / 0.01 ?F 100.0 ?F / 0.1 ?F 9999 ?F / 1 ?F 100 ?F to 1000 ?F |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 ?F | |
| Accuracy | 5% + 20% | |
| Lo-Z Capacitance | Range | 1 nF to 500 ?F |
| Accuracy | 10% + 2 typical | |
| Temperature² (Type-K thermocouple) | Range/resolution | -40°C to 400°C / 0.1°C |
| Accuracy | 1% + 10² | |
| Range/resolution | -40°F to 752°F / 0.2°F | |
| Accuracy | 1% + 18² | |
| AC ?A true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 ?A / 0.1 ?A |
| Accuracy | 1.5% + 3 | |
| DC ?amps | Range/resolution | 600.0 ?A / 0.1 ?A |
| Accuracy | 1.0% + 2 | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years |