Fluke 572-2 High Temperature Infrared Thermometer

Category: TEMPERATURE

Model: IR Thermometer

Avaibility: AVAILABLE

Call For Price

Specifications: 572-2 High Temperature Infrared Thermometer

Specifications: 572-2 High Temperature Infrared Thermometer

Infrared Measurements
Infrared temperature range-30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)? 0°C: ± 1°C or ± 1% of the reading, whichever is greater
? -10°C to < 0°C: ±2°C
< -10°C: ±3°C
? 32°F: ± 2°F or ± 1% of the reading, whichever is greater
? 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution0.1°C / 0.1°F
Distance: Spot60:1 (calculated at 90% energy)
Minimum spot size19 mm
Laser sightingOffset dual laser, output < 1 mW
Spectral response8 ?m to 14 ?m
Response time (95%)< 500 ms
EmissivityDigitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range-270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)< -40°C: ±(1°C + 0.2° / 1°C)
? -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
? -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple0.1°C / 0.1°F
K-type thermocouple repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarmsAudible and two-color visual
Min/Max/Avg/DifYes
Switchable celsius and fahrenheitYes
BacklightTwo levels, normal and extra bright for darker environments
Probe inputK-type thermocouple simultaneous display of probe and IR temperature
Trigger lockYes
Data storage99 points
DisplayDot matrix 98 x 96 pixels with function menus
CommunicationUSB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe)-40°C to 260°C (-40°F to 500°F)
Accuracy±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and complianceIEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F)
Relative humidity10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude2000 meters above mean sea level
Weight0.322 kg (0.7099 lb)
Power2 AA batteries
Battery life8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)

OTHER PRODUCT

We Offer Many Product For All Your Needs

Need help buying the right product?

We’ll assist you for further information, application assistance, or to schedule a technical meeting.